RF Conductor LossWheeler Incremental InductanceRamo-Whinnery-van DuzerIPC-4562
High-Frequency Skin Effect Depth & AC Resistance Calculator
Evaluates the skin effect penetration depth δ, effective copper conduction thickness, and high-frequency conductor resistance multiplication factor for RF & microwave PCBs.
Engineering Units & Substrate
Parameters & Geometry Inputs
Signal Frequency (f in MHz)(信号频率)
MHz
Copper Conductivity (σ)
5.8 × 10⁷ S/m (Annealed Cu)
Standard standard electrolytic copper foil
MICROSTRIP Cross-Section CAD
Scale: Dynamic Auto-Fit (mm)
Copper Conductor
Dielectric Core (FR-4/Rogers)
EM / Heat Flux Lines
Skin Penetration Depth (δ)Nominal Target
2.09μm
63% Current Conduction Depth
Fab Tolerance (±10%):1.88 - 2.30 μm
Skin Depth in Mils
0.082mil
AC Resistance Factor (Rac/Rdc)
× 8.37
1oz Copper Utilization
11.9 %
Recommended Finish
ENIG or Immersion Silver
ChipPCBA DFM Ready
Fast-Turn FabApply Parameters to Instant PCB Quote
Directly port your calculated geometry and impedance specifications into ChipPCBA's intelligent pricing engine with automated DFM checks.
Exported Parameters:
Copper:1ozMaterial:Rogers RO4350B
Apply to PCB Quote
24h Turnaround
IPC Class 2/3
Free DFM Review